<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15365</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: please close access door
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Make sure that all panels and access doors are properly closed.  Then
select the RESUME button from the workstation dialog box. If the problem
persists, call Creo Service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Make sure that all panels and access doors are properly closed.  Type
"mask" to see the status of the door open signal. If there is an exclamation
mark (!) preceding "Door is open", then the door signal is active and the access
doors should be open.  If the access doors are all closed, then there is a
problem with the door switch wiring or sensor/magnet alignment. Check the
door sensor connector (J19) on the card-cage backplane.
</text></DescriptionText>
</ServiceInformation>
<Cause>
An access door or panel was opened while the stepper motor was moving.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/mask.xml</LinkAddress><LinkTitle>Command: mask</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:05 2008 PST
</Updated>
<Links>
</Links>
</Error>